Serum Uromodulin as a Residual-Function Marker in Patients on Dialysis

Two CJASN papers examine serum uromodulin as a residual-function marker in dialysis. In 151 Geneva hemodialysis patients, it discriminated residual urea clearance of at least 2 ml/min per 35 L with an AUC of 0.891 (95% CI 0.839 to 0.944). Combined with β2-microglobulin, the AUC was 0.923 (95% CI 0.883 to 0.964), classifying 85% without a urine collection. A Chicago letter found median levels of 3.8 ng/ml in 60 hemodialysis patients and 9.7 ng/ml in 22 peritoneal dialysis patients.

Summary: Two CJASN papers examine serum uromodulin as a marker of residual kidney function (RKF) in dialysis. In 151 hemodialysis patients in Geneva, predialysis serum uromodulin discriminated residual urea clearance (KRU) of at least 2 ml/min per 35 L with an AUC of 0.891 (95% CI 0.839 to 0.944). Adding β2-microglobulin improved discrimination (AUC 0.923; 95% CI 0.883 to 0.964) and classified 85% of patients without a urine collection. In a Chicago letter of 60 hemodialysis and 22 peritoneal dialysis patients, uromodulin remained detectable at very low eGFR, with a higher median in the shorter-vintage peritoneal dialysis group (9.7 vs 3.8 ng/ml). This is observational work, not a trial of incremental dialysis outcomes.

Why this matters

RKF informs incremental hemodialysis, but timed urine collections are inconvenient and often skipped. Filtration markers in blood can estimate residual function without urine collection. In the NECOSAD validation cohort of 826 hemodialysis and peritoneal dialysis patients, Shafi et al. reported AUCs of 0.850 for β2-microglobulin, 0.821 for β-trace protein, and 0.796 for cystatin C for detecting urinary urea clearance of at least 2 ml/min, compared with 0.663 for a urea plus creatinine equation. In 341 patients on incremental high-flux hemodialysis or hemodiafiltration, Vilar et al. reported an AUC of 0.91 for predialysis β2-microglobulin for residual urea clearance of at least 2 ml/min/1.73 m². High-flux hemodialysis and hemodiafiltration remove these markers. Serum uromodulin, produced in the loop of Henle and distal tubule, is being studied as a marker of functional tubular mass. The Geneva study asks whether that tubular-mass signal adds to the filtration signal from β2-microglobulin (combined AUC 0.923).

What the two studies did

Jaques et al. (Geneva University Hospitals and the University of Zurich; CJASN, October 15, 2026) conducted a prospective observational hemodialysis study. Wright et al. (University of Chicago; IRB 21-0303; CJASN, September 29, 2026) published a research letter.

What they found

Geneva uromodulin AUC for KRU of at least 2 ml/min per 35 L was 0.891 (95% CI 0.839 to 0.944), similar to β2-microglobulin (AUC 0.877; P=0.66). The combined model reached an AUC of 0.923 (95% CI 0.883 to 0.964), better than either marker alone (versus uromodulin P=0.03; versus β2-microglobulin P=0.01). A gray-zone strategy classified 76% of patients with uromodulin alone (negative predictive value 97%, positive predictive value 84%) and 85% with the combined model, without a urine collection. In nonanuric patients, the AUC fell to 0.833, with PPV 84%, and urine collection was avoided in 80% of that subgroup.

Chicago uromodulin was detectable at very low eGFR. Median eGFR was 7 ml/min per 1.73 m² (IQR 6-8) on hemodialysis and 5 ml/min per 1.73 m² (IQR 3-6) on peritoneal dialysis. Median serum uromodulin was 3.8 ng/ml (IQR 1.3-7.7) in hemodialysis patients (median vintage 4.0 years, IQR 2.0-8.5) and 9.7 ng/ml (IQR 4.5-16.0) in the shorter-vintage peritoneal dialysis group (median vintage 1.4 years, IQR 0.4-3.1). The posthemodialysis median was 4.0 ng/ml (IQR 1.7-7.0).

Limits to keep in mind

Clinical takeaways

Sources